(a) Check the rear height control sensor RH: (C1713).
(1) Remove the rear height control sensor RH
.
(2) Connect 3 dry cell batteries of 1.5 V in series.
(3) Connect the positive (+) end of the batteries to terminal 3 (SHB) of the height control sensor and the negative (-) end of the batteries to terminal 1 (SHG). While slowly moving the sensor link up and down, measure the voltage between terminal 2 (SHRR) and terminal 1 (SHG).
(4) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
|
Tester Connection
|
Sensor Condition
|
Specified Condition
|
|
1 (SHG) - 2 (SHRR)
|
High (45°)
|
4.4 to 4.6 V
|
|
Normal (0°)
|
2.3 to 2.6 V
|
|
Low (-45°)
|
0.4 to 0.6 V
|
NOTICE:
Do not apply a voltage of more than 6 V.
|